PROSINE 2.0 INVERTER•CHARGER USER’S MANUAL
66
445-0089-01-01
PART 4: OPERATION IN CHARGER MODE
➢
➢➢
➢
To operate the inverter•charger in Charger mode
1. Turn on the PROsine’s ON/OFF/REM switch.
2. Connect AC shorepower.
• The batteries are charged according to the three-step algorithm you
have selected.
• The READY LED comes on when the charge cycle is complete.
• You can interrupt the charge cycle any time if you don’t have time to
wait for a full charge.
• To maintain optimal performance in flooded batteries, an occasional
equalize cycle may be required.
3. While the batteries are being charged, you can monitor which stage they
are in by viewing PROsine System Mode on the PROsine—Diagnostics
menu. See page 58.
For more detailed descriptions of Bulk, Absorption, and Float charging
modes, see Appendix C: “Batteries”.
WARNING
Review the
“Important Safety Instructions‚” on page xv
before operating
the inverter•charger.
During charging, batteries may generate explosive gasses. Thoroughly
ventilate the area around the batteries and ensure that there are no sources of
flames or sparks in the vicinity.
Study all battery manufacturer’s precautions such as removing or not
removing cell caps while charging and recommended rates of charge.
NOTE
If you are charging a non-sealed battery, add distilled water to each cell until
battery acid reaches the level specified by the manufacturer. This helps prevent
over-heating and purges excessive gases from the cells. Do not overfill. For a
battery without cell caps, follow the manufacturer’s recharging instructions
carefully.