Default Values for PROsine 2.0 System
Table 1 lists the default settings for the PROsine 2.0 system. Record your
settings in the right-hand column after you have configured the
inverter•charger. This information will be valuable if you need to reconfigure
your system or call Xantrex Customer Service.
Table 1 Default Values: Inverter•Charger
Item Default Value Your Settings
NOTE
At a minimum, configure the items marked with a
**
after installation.
Adjustable From the Configure PROsine—Basic Menu
AC Breaker Size 15 amps
**
Adjustable From the Configure PROsine—Advanced Menu
Load Sensing OFF
Load Sense Power 100 Watts
Load Sense Interval 1 second
Low AC Transfer (V) 90V
Low AC Transfer (Hz) 55Hz
High AC Transfer (V) 130V
High AC Transfer (Hz) 65Hz
AC Series Mode Standalone
Inverter Low V Shutdown 10V
Run Without Panel OFF
Inverter Enabled on Reset
Without Panel
OFF
Charger Enabled on Reset
Without Panel
OFF
Auto Restart After Error OFF
**
Adjustable From the Configure Display Panel Menu
Audible Alarm OFF
LCD Backlight Mode Auto
LCD Backlight Brightness 50%
LCD Backlight Timeout 20 seconds
Temperature Farenheit