5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
5-9
5
Basic Functions That Require Setting before Operation
SigmaWin+ Panel Operator or Digital Operator
When Writ-
ing Is Pro-
hibited
Reference
Menu Bar
Button
SigmaWin+ Function
Name
Fn No. Utility Function Name
Setup
Origin Search
Fn003 Origin Search
Cannot be
executed.
page 7-25
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Cannot be
executed.
page 5-52
Speed/Torque Reference
Offset Adjustment
Fn009
Autotune Analog (Speed/
Torque) Reference Offset
Cannot be
executed.
page 6-22,
page 6-38
Fn00A
Manually Adjust Speed Refer-
ence Offset
Cannot be
executed.
page 6-22
Fn00B
Manually Adjust Torque Ref-
erence Offset
Cannot be
executed.
page 6-38
Analog Monitor Output
Adjustment
Fn00C
Adjust Analog Monitor Output
Offset
Cannot be
executed.
page 9-8
Fn00D
Adjust Analog Monitor Output
Gain
Cannot be
executed.
page 9-8
Motor Current Detection
Offset Adjustment
Fn00E
Autotune Motor Current
Detection Signal Offset
Cannot be
executed.
page 6-97
Fn00F
Manually Adjust Motor Cur-
rent Detection Signal Offset
Cannot be
executed.
Multiturn Limit Setting
Fn013
Multiturn Limit Setting after
Multiturn Limit Disagreement
Alarm
Cannot be
executed.
page 6-80
Reset Configuration Error
of Option Module
Fn014
Reset Option Module Config-
uration Error
Cannot be
executed.
page 12-43
Initialize Vibration Detection
Level
Fn01B
Initialize Vibration Detection
Level
Cannot be
executed.
page 6-93
Setting the Origin of the
Absolute Linear Encoder
Fn020
Set Absolute Linear Encoder
Origin
Cannot be
executed.
page 5-54
Reset Motor Type Alarm Fn021 Reset Motor Type Alarm
Cannot be
executed.
page 5-16
Software Reset Fn030 Software Reset
Can be
executed.
page 6-91
Polarity Detection Fn080 Polarity Detection
Cannot be
executed.
page 5-29
Tuning-less Level Setting Fn200 Tuning-less Level Setting
Cannot be
executed.
page 8-15
EasyFFT Fn206 Easy FFT
Cannot be
executed.
page 8-85
Parameters
Initialize Servo
*
Fn005 Initialize Parameters
Cannot be
executed.
page 5-10
Tuning
Autotuning without Refer-
ence Input
Fn201
Advanced Autotuning with-
out Reference
Cannot be
executed.
page 8-23
Autotuning with Reference
Input
Fn202
Advanced Autotuning with
Reference
Cannot be
executed.
page 8-35
Custom Tuning Fn203 One-Parameter Tuning
Cannot be
executed.
page 8-42
Anti-Resonance Control
Adjustment
Fn204
Adjust Anti-resonance Con-
trol
Cannot be
executed.
page 8-51
Vibration Suppression Fn205 Vibration Suppression
Cannot be
executed.
page 8-55
Monitor Product Information
Fn011 Display Servomotor Model
Can be
executed.
page 9-2
Fn012 Display Software Version
Can be
executed.
Fn01E
Display SERVOPACK and
Servomotor IDs
Can be
executed.
page 9-2
Fn01F
Display Servomotor ID from
Feedback Option Module
Can be
executed.

Table of Contents