12.11 o: Keypad-Related Settings
1044 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
When you set o2-03 = 1 [Set defaults], the drive saves changed parameter settings as user parameter setting values in
a part of the memory that is isolated from drive parameters.
When you set A1-03 = 1110 [Initialize Parameters = User Initialization] to initialize the drive, the drive resets the
internal parameter setting values to those user parameter setting values.
0 : No change
1 : Set defaults
Saves changed parameter setting values as user default settings.
Set o2-03 = 1 then push to save the user parameter setting values. After the drive saves the setting value, o2-03
automatically resets to 0.
2 : Clear all
Deletes all of the saved user parameter setting values.
Set o2-03 = 2 then push to clear the user parameter setting values. The drive will automatically reset o2-03 to 0. If
you delete the user parameter setting values, you cannot set A1-03 = 1110 to initialize parameters.
o2-04: Drive Model (KVA) Selection
No.
(Hex.)
Name Description
Default
(Range)
o2-04
(0508)
Drive Model (KVA)
Selection
Sets the Drive Model code. Set this parameter after replacing the control board.
Determined by the drive
(-)
NOTICE: Set o2-04 [Drive Model (KVA) Selection] correctly. If you set this parameter incorrectly, it will decrease drive performance,
cause the protection function to operate incorrectly, and cause damage to the drive.
Note:
When the setting value of o2-04 changes, related parameter setting values also change. Refer to Defaults by Drive Model and Duty Rating
ND/HD on page 672 for more information.
These tables list the relation between o2-04 setting values and drive models.
Table 12.74 Three-Phase 200 V Class
Drive Model o2-04 Setting
2004 0062
2006 0063
2008 0064
2010 0065
2012 0066
2018 0067
2021 0068
2030 006A
2042 006B
2056 006D
Drive Model o2-04 Setting
2070 006E
2082 006F
2110 0070
2138 0072
2169 0073
2211 0074
2257 0075
2313 0076
2360 0077
2415 0078
Table 12.75 Three-Phase 400 V Class
Drive Model o2-04 Setting
4002 0092
4004 0093
4005 0094
4007 0095
4009 0096
4012 0097
4018 0099
Drive Model o2-04 Setting
4023 009A
4031 009C
4038 009D
4044 009E
4060 009F
4075 00A1
4089 00A2
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV