5.2 European Standards
252 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Model Terminal
Recomm. Gauge
mm
2
Applicable Gauge
(IP20 Applicable Gauge
*1
)
mm
2
Wire Stripping
Length
*2
mm
Terminal Screw
Size and Shape
Tightening Torque
Nm (lbfin)
4477
R/L1, S/L2, T/L3 120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
35
(310)
U/T1, V/T2, W/T3 95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
35
(310)
-, +1 95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
35
(310)
+3 70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
35
(310)
150
50 - 150
(-)
-
M12
32 - 40
(283 - 354)
4568
R/L1, S/L2, T/L3 120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
35
(310)
U/T1, V/T2, W/T3 95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
35
(310)
-, +1 95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
35
(310)
+3 70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
35
(310)
95 × 2P
60 - 150
(-)
-
M12
32 - 40
(283 - 354)
4605
R/L1, S/L2, T/L3 120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
35
(310)
U/T1, V/T2, W/T3 95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
35
(310)
-, +1 95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
35
(310)
+3 70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
35
(310)
95 × 2P
60 - 150
(-)
-
M12
32 - 40
(283 - 354)
4720
R/L1, S/L2, T/L3 120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
35
(310)
U/T1, V/T2, W/T3 95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
35
(310)
-, +1 95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
35
(310)
+3 70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
35
(310)
95 × 2P
60 - 150
(-)
-
M12
32 - 40
(283 - 354)
*1 For IP20 protection, use wires that are in the range of applicable gauges.
*2 Remove insulation from the ends of wires to expose the length of wire shown.
*3 For wire gauges more than 30 mm
2
, tighten to a tightening torque of 4.1 N∙m to 4.5 N∙m (36 lbf∙in to 40 lbf∙in).
*4 Install a GFCI with this wire gauge to maintain compliance with IEC/EN 61800-5-1:2007.