Parameter List
11
11.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 677
No.
*1
Name Unit Default
- Drive Model - 2110 2138 2169 2211
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 0070 0072 0073 0074
E2-11
(E4-11)
Motor Rated
Power
kW 22 30 30 37 37 45 45 55
b3-08
Speed
Estimation
ACR P Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 2.00
b8-04
Energy Saving
Coefficient
Value
- 51.79 46.27 46.27 38.16 38.16 35.78 35.78 31.35
C5-17
(C5-37)
Motor Inertia kgm
2
0.165 0.220 0.220 0.273 0.273 0.333 0.333 0.490
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 77.2 105 105 131 131 160 160 190
E2-02
(E4-02)
Motor Rated
Slip
Hz 1.7 1.8 1.8 1.33 1.33 1.6 1.6 1.43
E2-03
(E4-03)
Motor No-
Load Current
A 18.5 21.9 21.9 38.2 38.2 44 44 45.6
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 0.079 0.064 0.064 0.039 0.039 0.03 0.03 0.022
E2-06
(E4-06)
Motor
Leakage
Inductance
% 19.5 20.8 20.8 18.8 18.8 20.2 20.2 20.5
E2-10
(E4-10)
Motor Iron
Loss
W 538 699 699 823 823 852 852 960
E5-01
PM Motor
Code Selection
- 1210 1210 1212 1212 1213 1213 1214 1214
L2-02
Power Loss
Ride Through
Time
s 2 2 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 1 1.1 1.1 1.1 1.1 1.2 1.2 1.3
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.6 0.6 0.6 0.6 0.6 1 1 1
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 190 190 190 190 190 190 190 190
L3-24
Motor Accel
Time @ Rated
Torque
s 0.355 0.323 0.323 0.32 0.32 0.387 0.387 0.317
L8-02
Overheat
Alarm Level
°C 105 105 115 115 105 105 105 105
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2