11.21 Defaults by Drive Model and Duty Rating ND/HD
682 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
No.
*1
Name Unit Default
- Drive Model - 4009 4012 4018 4023
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 0096 0097 0099 009A
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP
(kW)
4
(3.0)
5
(4.0)
5
(4.0)
7.5
(5.5)
7.5
(5.5)
10
(7.5)
10
(7.5)
15
(11)
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 5.7 7 7 9.8 9.8 13.3 13.3 19.9
E2-02
(E4-02)
Motor Rated
Slip
Hz 2.7 2.7 2.7 1.5 1.5 1.3 1.3 1.7
E2-03
(E4-03)
Motor No-
Load Current
A 1.9 2.3 2.3 2.6 2.6 4 4 5.6
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 4.360 3.333 3.333 1.595 1.595 1.152 1.152 0.922
E2-06
(E4-06)
Motor
Leakage
Inductance
% 19 19.3 19.3 18.2 18.2 15.5 15.5 19.6
E2-10
(E4-10)
Motor Iron
Loss
W 105 130 130 193 193 263 263 385
E5-01
PM Motor
Code Selection
- FFFF FFFF 1238 1238 123A 123A 123B 123B
L2-02
Power Loss
Ride Through
Time
s 0.5 0.5 0.5 0.5 0.8 0.8 1 1
L2-03
Minimum
Baseblock
Time
s 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.9
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 380 380 380 380 380 380 380 380
L3-24
Motor Accel
Time @ Rated
Torque
s 0.145 0.154 0.154 0.168 0.168 0.175 0.175 0.265
L8-02
Overheat
Alarm Level
°C 100 100 100 100 105 105 105 105
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
n1-16
Hunting
Prevention
High Fc Gain
- 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
n5-02
Motor Inertia
Acceleration
Time
s 0.145 0.154 0.154 0.168 0.168 0.175 0.175 0.265
*1 Parameters within parentheses are for motor 2.