Parameter Details
12
12.6 E: Motor Parameters
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 823
• For more conditions, contact Yaskawa or your nearest sales representative.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103, T103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4720, T140 - T720
ND: 2211 - 2415, 4103 - 4720, T103 - T720
C : Const Trq, 60Hz base, 90Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at
more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103, T103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4720, T140 - T720
ND: 2211 - 2415, 4103 - 4720, T103 - T720
D : Const Trq, 60Hz base, 120Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at
more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103, T103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4720, T140 - T720
ND: 2211 - 2415, 4103 - 4720, T103 - T720
E : Const Trq, 60Hz base, 180Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate at
more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.