12.6 E: Motor Parameters
824 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103, T103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4720, T140 - T720
ND: 2211 - 2415, 4103 - 4720, T103 - T720
F : V/f Pattern Selection
Set E1-04 to E1-13 [V/f Pattern for Motor 1] to set the values for this custom pattern.
The default settings are the same as Setting Value 1 [Const Trq, 60Hz base, 60Hz max].
■ E1-04: Maximum Output Frequency
No.
(Hex.)
Name Description
Default
(Range)
E1-04
(0303)
Maximum Output Frequency
Sets the maximum output frequency for the V/f pattern.
Determined by A1-02 and
E5-01
(Determined by A1-02 and
E5-01)
■ E1-05: Maximum Output Voltage
No.
(Hex.)
Name Description
Default
(Range)
E1-05
(0304)
Maximum Output Voltage
Sets the maximum output voltage for the V/f pattern.
200 V Class: 230.0 V, 400 V:
460.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
■ E1-06: Base Frequency
No.
(Hex.)
Name Description
Default
(Range)
E1-06
(0305)
Base Frequency
Sets the base frequency for the V/f pattern.
Determined by A1-02 and
E5-01
(0.0 - E1-04)
■ E1-07: Mid Point A Frequency
No.
(Hex.)
Name Description
Default
(Range)
E1-07
(0306)
Mid Point A Frequency
Sets a middle output frequency for the V/f pattern.
Determined by A1-02
(0.0 - E1-04)
■ E1-08: Mid Point A Voltage
No.
(Hex.)
Name Description
Default
(Range)
E1-08
(0307)
Mid Point A Voltage
Sets a middle output voltage for the V/f pattern.
Determined by A1-02,C6-
01 and o2-04
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Note:
Default setting is determined by A1-02 [Control Method Selection], C6-01 [Normal / Heavy Duty Selection], and o2-04 [Drive Model
Selection].