Configuring Basic Features
515
Parameters
Permitted Values
Default
Dsskey->Line key/Programable Key->Line
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Account ID
linekey.X.value/ programablekey.X.value/
expansion_module.X.key.Y.value
String within 99
characters
Blank
Description:
Configures the intercom number.
For line keys:
X ranges from 1 to 29 (for SIP-T48G/S)
X ranges from 1 to 27 (for SIP-T46G/T46S/T29G)
X ranges from 1 to 15 (for SIP-T42G/T42S/T41P/T41S)
X ranges from 1 to 21 (for SIP-T27P/T27G)
X ranges from 1 to 3 (for SIP-T40P/T40G/T23P/T23G)
X ranges from 1 to 2 (for SIP-T21(P) E2)
For programable keys:
X=1-10, 12-14 (for SIP-T48G/T48S/T46G/T46S)
X=1-10, 13 (for SIP-T42G/T42S/T41P/T41S/T40P/T40G)
X=1-14 (for SIP-T29G/T27P/T27G)
X=1-10, 14 (for SIP-T23P/T23G/T21(P) E2)
X=1-9, 13, 14 (for SIP-T19(P) E2)
For ext keys:
For SIP-T48G/T48S/T46G/T46S:
X ranges from 1 to 6, Y ranges from 1 to 40.
For SIP-T29G/T27P/T27G:
X ranges from 1 to 6, Y ranges from 1 to 20, 22 to 40 (Ext key 21 cannot be configured).
Example:
linekey.2.value = 1008
Web User Interface:
Dsskey->Line key/Programable Key->Value
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Value
linekey.X.pickup_value/
programablekey.X.pickup_value/
expansion_module.X.key.Y.pickup_value
String within 256
characters
Blank

Table of Contents

Other manuals for Yealink SIP-T2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T2 Series and is the answer not in the manual?

Yealink SIP-T2 Series Specifications

General IconGeneral
BrandYealink
ModelSIP-T2 Series
CategoryIP Phone
LanguageEnglish

Related product manuals