Page 4-54 110XiIIIPlus Maintenance Manual 13185L-002 Rev. A 1/24/06
Section 4 Maintenance
Replace the Cutter Components
Remove and Install the Cutter Main Link
1. Refer to RRP No. 1 on page 4-14. Turn the printer Off (O), remove the AC power
cord and data cables.
2. Refer to RRP No. 2 on page 4-16 and remove the electronics cover.
3. Refer to RRP No. 3 on page 4-17 and remove the power supply.
4. Refer to Figure 4-32. Remove the E-ring securing the cutter main link to the short
arm side of the cutter slotted link.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer
from the power source before performing the following maintenance.
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it
is highly recommended the technician wear an antistatic wrist strap connected
to the printer chassis.
Caution:
This installation must be performed by a qualified service technician.
Caution:
Wear protective eyewear when removing E-rings, C-clips, snap rings, and
springs. All of these are under tension and could fly off while being removed.