RS-232 Interface 6 - 5
RS-232 Host Parameters (continued)
Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or
CUTE-LP/LG bar code readers transmits the code ID characters listed in Table 6-3. These code ID characters are
not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID
feature for these terminals.
Table 6-3 Terminal Specific Code ID Characters
Code Type ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-Nixdorf
Mode B/
OPOS/JPOS
Olivetti Omron CUTE
UPC-A
AAA A AAA
UPC-E
EEC C CENone
EAN-8/JAN-8
FF FF B B B FF None
EAN-13/JAN-13
FFA A AFA
Code 39
C <len> None M M M <len> C <len> 3
Code 39 Full ASCII
None None M M None None 3
Codabar
N <len> None N N N <len> N <len> None
Code 128
L <len> None K K K <len> L <len> 5
I 2 of 5
I <len> None I I I <len> I <len> 1
Code 93
None None L L L <len> None None
D 2 of 5
H <len> None H H H <len> H <len> 2
GS1-128
L <len> None P P P <len> L <len> 5
MSI
None None O O O <len> None None
Bookland EAN
FFA A AFNone
Trioptic
None None None None None None None
Code 11
None None None None None None None
IATA
H<len> None H H H<len> H<len> 2
Code 32
None None None None None None None
GS1 DataBar
Variants
None None E E None None None
PDF417
None None Q Q None None 6
Data Matrix
None None R R None None 4
GS1 Data Matrix
None None W W None None None
QR Codes
None None U U None None 7
GS1 QR
None None X X None None None