Standard Parameter Defaults A - 9
Convert Code 39 to Code 32
(Italian Pharmacy Code)
86 56h Disable
11-38
Code 32 Prefix 231 E7h Disable
11-38
Set Length(s) for Code 39 18, 19 12h, 13h 1 to 55
11-39
Code 39 Check Digit Verification 48 30h Disable
11-40
Transmit Code 39 Check Digit 43 2Bh Disable
11-41
Code 39 Full ASCII Conversion 17 11h Disable
11-41
Code 39 Security Level 750 F1h EEh Security Level 1
11-42
Code 39 Reduced Quiet Zone 1209 F8h 04h B9h Disable
11-44
Code 93
Code 93 9 09h Enable
11-45
Set Length(s) for Code 93 26, 27 1Ah, 1Bh 1 to 55
11-45
Code 11
Code 11 10 0Ah Disable
11-47
Set Lengths for Code 11 28, 29 1Ch, 1Dh 4 to 55
11-47
Code 11 Check Digit Verification 52 34h Disable
11-49
Transmit Code 11 Check Digit(s) 47 2Fh Disable
11-50
Interleaved 2 of 5 (ITF)
Interleaved 2 of 5 (ITF) 6 06h Enable
11-51
Set Lengths for I 2 of 5 22, 23 16h, 17h 6 to 55
11-51
I 2 of 5 Check Digit Verification 49 31h Disable
11-53
Transmit I 2 of 5 Check Digit 44 2Ch Disable
11-54
Convert I 2 of 5 to EAN 13 82 52h Disable
11-54
I 2 of 5 Security Level 1121 F8h 04h 61h Security Level 1
11-55
I 2 of 5 Reduced Quiet Zone 1210 F8h 04h BAh Disable
11-56
Discrete 2 of 5 (DTF)
Discrete 2 of 5 5 05h Disable
11-57
Set Length(s) for D 2 of 5 20, 21 14h 15h 1 to 55
11-57
Table A-1 Parameter Defaults (Continued)
Parameter
Parameter
Number
1
SSI
Number
2
Default
Page
Number
1. Parameter number decimal values are used for programming via RSM commands.
2. SSI number hex values are used for programming via SSI commands.