Chapter 31 Log Setting
NR/FWA Outdoor Series User’s Guide
261
The following table describes the fields in this screen.
31.2.1 Example Email Log
An ‘End of Log’ message displays for each mail in which a complete log has been sent. The following is
an example of a log sent by email.
• You may edit the subject title.
• The date format here is Day-Month-Year.
Table 113 Maintenance > Log Setting
LABEL DESCRIPTION
Syslog Settings
Syslog Logging Slide the switch to the right to enable syslog logging.
Mode Select Remote to have the Zyxel Device send it to an external syslog server.
Select Local File to have the Zyxel Device save the log file on the Zyxel Device itself.
Select Local File and Remote to have the Zyxel Device save the log file on the Zyxel Device itself
and send it to an external syslog server.
Note: A warning appears upon selecting Remote or Local File and Remote. Just click
OK to continue.
Syslog Server Enter the server name or IP address of the syslog server that will log the selected categories of
logs.
UDP Port Enter the port number used by the syslog server.
E-mail Log Settings
E-mail Log
Settings
Slide the switch to the right to allow the sending through email the system and security logs to
the email address specified in Send Log to.
Note: Make sure that the Mail Server Address field is not left blank in the
Maintenance > E-mail Notifications screen.
Mail Account Select a server specified in Maintenance > E-mail Notifications to send the logs to.
System Log Mail
Subject
This field allows you to enter a descriptive name for the system log email (for example Zyxel
System Log). Up to 127 printable characters are allowed for the System Log Mail Subject
including special characters inside the square brackets [!#%()*+,–./:=?@[]\{}~].
Security Log Mail
Subject
This field allows you to enter a descriptive name for the security log email (for example Zyxel
Security Log). Up to 127 printable characters are allowed for the Security Log Mail Subject
including special characters inside the square brackets [!#%()*+,–./:=?@[]\{}~].
Send Log to This field allows you to enter the log’s designated email recipient. The log’s format is plain text
file sent as an email attachment.
Send Alarm to This field allows you to enter the alarm’s designated e-mail recipient. The alarm’s format is plain
text file sent as an email attachment.
Alarm Interval Select the frequency of showing of the alarm.
Active Log
Syslog Debug
Logging
Slide the switch to the right to enable syslog debug logging.
System Log Select the categories of System Logs that you want to record.
Security Log Select the categories of Security Logs that you want to record.
Apply Click Apply to save your changes.