EasyManua.ls Logo

ABB ACS880 N5700 Series - Page 223

ABB ACS880 N5700 Series
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
0.000 mA / real32(Visible when 14.1 Module 1 type = FAIO-01)
Defines the minimum output value for analog output
AO1.
See also drawing at parameter 14.80 AO1 source min.
AO1 out at AO1 src
min
14.82
1000 = 1 mA / 1000 =
1 mA
Minimum AO1 output value.0.000 ... 20.000 mA
10.000 mA / real32(Visible when 14.1 Module 1 type = FIO-11)
Defines the maximum output value for analog output
AO1.
See also drawing at parameter 14.80 AO1 source min.
AO1 out at AO1 src
max
14.83
1000 = 1 mA / 1000 =
1 mA
Maximum AO1 output value.0.000 ... 22.000 mA
10.000 mA / real32(Visible when 14.1 Module 1 type = FAIO-01)
Defines the maximum output value for analog output
AO1.
See also drawing at parameter 14.80 AO1 source min.
AO1 out at AO1 src
max
14.83
1000 = 1 mA / 1000 =
1 mA
Maximum AO1 output value.0.000 ... 20.000 mA
- / real32(Visible when 14.1 Module 1 type = FAIO-01)
Displays the value of AO2 in mA.
This parameter is read-only.
AO2 actual value14.86
1000 = 1 mA / 1000 =
1 mA
Value of AO2.0.000 ... 22.000 mA
Zero / uint32(Visible when 14.1 Module 1 type = FAIO-01)
Selects a signal to be connected to analog output AO2.
Alternatively, sets the output to excitation mode to
feed a constant current to a temperature sensor.
For the selections, see parameter 14.77 AO1 source.
AO2 source14.87
0.000 mA / real32(Visible when 14.1 Module 1 type = FAIO-01)
Forced value that can be used instead of the selected
output signal. See parameter 14.71 AO force selection.
AO2 force data14.88
1000 = 1 mA / 1000 =
1 mA
Forced value of analog output AO2.0.000 ... 20.000 mA
0.100 s / real32(Visible when 14.1 Module 1 type = FAIO-01)
Defines the filtering time constant for analog output
AO2. See parameter 14.79 AO1 filter time.
AO2 filter time14.89
1000 = 1 s / 1000 = 1
s
Filter time constant.0.000 ... 30.000 s
Parameters 223

Table of Contents

Related product manuals