Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
15As selection 1 x Pt1000 analog I/O, but with three
sensors connected in series. Using multiple sensors
improves measurement accuracy significantly.
3 x Pt1000 analog
I/O
16Pt1000 sensor connected to encoder interface 1. See
parameters 91.21 Module 1 temp sensor type and 91.22
Module 1 temp filter time.
Note: Pt1000 sensor is supported with FEN-11 and
FEN-31 encoder modules only.
Pt1000 encoder
module 1
17Pt1000 sensor connected to encoder interface 2. See
parameters 91.24 Module 2 temp sensor type and 91.25
Module 2 temp filter time.
Note: Pt1000 sensor is supported with FEN-11 and
FEN-31 encoder modules only.
Pt1000 encoder
module 2
130 ° / real32Defines the fault limit for temperature monitoring
function 2.
When measured temperature 2 exceeds the limit, the
drive trips on fault 4982 External temperature 2.
The unit is selected by parameter 96.16 Unit selection.
Note: With °F, the range is -76…1832. With a PTC sensor,
the range is 0…5000 ohms.
Temperature 2 fault
limit
35.22
1 = 1 ° / 1 = 1 °Fault limit for temperature monitoring function 2.-60...1000 °
110 ° / real32Defines the warning limit for temperature monitoring
function 2. When measured temperature 2 exceeds the
limit, a warning
(A492 External temperature 2) is generated.
The unit is selected by parameter 96.16 Unit selection.
Note: With °F, the range is -76…1832. With a PTC sensor,
the range is 0…5000 ohms.
Temperature 2
warning limit
35.23
1 = 1 ° / 1 = 1 °Warning limit for temperature monitoring function 2.-60...1000 °
Not selected / uint32Selects the input for parameter 35.21 Temperature 2
source, selections KTY84 analog I/O, 1 x Pt100 analog
I/O, 2 x Pt100 analog I/O, 3 x Pt100 analog I/O and
Direct temperature.
Temperature 2 AI
source
35.24
0None.Not selected
1Analog input AI1 on the control unit.AI1 actual value
2Analog input AI2 on the control unit.AI2 actual value
See Terms and abbreviations (page 130).Other [value]
0 °C / real32Defines the calibration of temperature 2.
See parameter 35.17 Temperature 1 calibration.
Temperature 2
calibration
35.27
1 = 1 °C / 1 = 1 °CCalibration of temperature 2 in celsius.-30...1000 °C
- / uint16Activates FPTC-xx thermistor protection modules
installed on the control unit of the drive. Using this
word, it is also possible to suppress the warnings (but
not faults) from each module.
FPTC configuration
word
35.30
1 = Yes: Module installed in slot 1.Module in slot 1b0
Parameters 347