Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
11.Enable
- / int32Displays the last known value of 86.8 Actual position
raw read from the encoder interface module.
This parameter is read-only.
Raw axis position
input retain
86.101
- / -Actual position.-2147483648...2147483647
increments
- / int32A backup value of 86.8 Actual position raw that is
preserved over a power cycle. The value is updated
together with the actual position, but is not affected
by the Preset position functionality unless selected as
retentive.
This parameter is read-only.
Raw axis position
backup retain
86.102
- / -Backup of raw actual position.-2147483648...2147483647
increments
Parameters 471