Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / real32Defines the maximum position limit.
If the actual position exceeds this value, a stop
command is activated, and Error stop indicated by
74.10 Position control actual status.
Note:
• The deceleration and jerk rates for stopping (75.31
and 75.32 respectively) must be higher than those
used for the base movement. Otherwise the
position limit is ignored and a warning (E205 Fast
Stop configuration) generated.
• The limit is ignored if homing is not done with a
non-absolute encoder (bit 6 or 7 of 86.1 Axis status
= 0).
• The maximum and minimum limits are disabled
if 86.60 and 86.61 are set to the same value, or if
modulo operation is in use (86.18 Modulo range
numerator > 0).
Maximum position86.60
1000 = 1 units / 1000
= 1 units
Maximum position.-2000000.000 ...
2000000.000 units
- / real32Defines the minimum position limit.
If the actual position falls below this value, a stop
command is activated, and Error stop indicated by
74.10 Position control actual status.
See the Notes at 86.60 Maximum position.
Minimum position86.61
1000 = 1 units / 1000
= 1 units
Minimum position.-2000000.000 ...
2000000.000 units
- / uint32Selects the signal source of the maximum position limit
switch. If the signal is removed, a stop command is
activated, and Error stop indicated by 74.10 Position
control actual status. Running in the forward direction
is prevented.
For the selections, see parameter 86.56 Latch 1 SW
input source.
Maximum position
limit source
86.63
- / uint32Selects the signal source of the minimum position limit
switch.
If the signal is removed, a stop command is activated,
and Error stop indicated by 74.10 Position control actual
status.
Running in the reverse direction is prevented.
For the selections, see parameter 86.56 Latch 1 SW
input source.
Minimum position
limit source
86.64
Enable / uint32Determines whether the backup position value (86.102
Raw axis position backup retain) is used to preset 86.2
Actual position upon the initialization after power-up.
0 = Actual position is read from the selected actual
position source upon initialization.
1 = 86.2 is set according to the value of 86.102 upon
initialization.
Position offset
retention
86.69
00.Disable
470 Parameters