Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1000 = 1 units/s^2 /
1 = 1 units/s^2
Maximum acceleration for jogging.0.000 ...
20000000.000
units/s^2
10.000 units/s^2 /
real32
Defines the maximum deceleration rate used during
jogging.
Jogging
deceleration
75.23
1000 = 1 units/s^2 /
1 = 1 units/s^2
Maximum deceleration for jogging.0.000 ...
20000000.000
units/s^2
0.000 units/s^3 /
real32
Defines the maximum jerk value to be used during
jogging.
Note: 0.000 = unlimited.
Jogging jerk75.24
1000 = 1 units/s^3 /
1 = 1 units/s^3
Maximum jerk for jogging.0.000 ...
20000000.000
units/s^3
20.000 units/s^2 /
real32
Defines the deceleration rate for stopping.
This value must be higher than that in the active profile.
Otherwise this value is ignored and a warning (E205
Fast Stop configuration) generated.
Stop deceleration75.31
1000 = 1 units/s^2 /
1 = 1 units/s^2
Deceleration rate for stopping.0.000 ...
20000000.000
units/s^2
0.000 units/s^3 /
real32
Defines the jerk value for stopping.
This value must be higher than that in the active profile.
Otherwise this value is ignored and a warning (E205
Fast Stop configuration) generated.
Note: 0.000 = unlimited.
Stop jerk75.32
1000 = 1 units/s^3 /
1 = 1 units/s^3
Deceleration rate for stopping.0.000 ...
20000000.000
units/s^3
0.000 units / real32Defines a preset position for several selections of
parameter 75.36 Preset position mode.
Preset position75.35
1000 = 1 units / 1 = 1
units
Preset position.-2000000.000 ...
2000000.000 units
Axis immediate /
int16
Selects the preset position mode.
See also 86.69 Position offset retention for the action
taken at power-up.
Preset position
mode
75.36
0Sets the actual axis position value to that of 75.35
Preset position.
Axis immediate
Parameters 451