Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1 = 1 % / 10000 = 1 %Voltage boost at zero speed in percent of nominal
motor voltage.
0.00 ... 50.00 %
Disabled / uint16Selects whether the temperature-dependent
parameters (such as stator or rotor resistance) of the
motor model adapt to actual (measured or estimated)
temperature or not.
See parameter group 35 Motor thermal protection for
selection of temperature measurement sources.
Motor model
temperature
adaptation
97.15
0Temperature adaptation of motor model disabled.Disabled
1Estimated temperature (35.1 Motor estimated
temperature) used for adaptation of motor model.
Estimated
temperature
2Measured temperature 1 (35.2 Measured temperature
1) used for adaptation of motor model.
Measured
temperature 1
3Measured temperature 2 (35.3 Measured temperature
2) used for adaptation of motor model.
Measured
temperature 2
Off / uint16Activates hexagonal motor flux pattern in the field
weakening area, i.e. above the limit defined by
parameter 97.19 Hexagonal field weakening point.
Note: This parameter is only effective in scalar motor
control mode.
See also section Hexagonal motor flux
pattern (page 95).
Hexagonal field
weakening
97.18
0The rotating flux vector follows a circular pattern.Off
1The flux vector follows a circular pattern below, and a
hexagonal pattern above, the hexagonal field
weakening point (97.19).
On
120.0 % / real32Defines the activation limit for hexagonal field
weakening (in percent of the field weakening point, i.e.
the frequency at which maximum output voltage is
reached). See parameter 97.18 Hexagonal field
weakening.
Note: This parameter is only effective in scalar motor
control mode.
Hexagonal field
weakening point
97.19
1 = 1 % / 1000 = 1 %Activation limit for hexagonal field weakening.0.0 ... 500.0 %
0.0 % / real32Unfiltered motor torque in percent of the nominal
motor torque.
Note: This parameter is read-only.
Motor torque
unfiltered
97.32
- / -Unfiltered motor torque.
For scaling, see parameter 46.3.
-1600.0 ... 1600.0 %
5.00 ms / real32Defines a filtering time for estimated speed See the
diagram on page 650.
Speed estimate
filter time
97.33
1 = 1 ms / 100 = 1 msFiltering time for estimated speed.0.00 ... 100.00 ms
Parameters 531