Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
0.00 % / real32Defines the maximum allowed stator flux assistance
reference for boosting the flux when needed.
Stator flux assistance improves the efficiency of the
drive in high load conditions with externally-excited
synchronous motors.
The function is activated when a non-zero value is set
to parameter 97.78. The flux is boosted between
parameters 97.7 and 97.7 + 97.78, when needed.
Maximum flux
reference assistance
97.78
1 = 1 % / 100 = 1 %Maximum flux reference assistance.0.00 ... 200.00 %