Parameters and firmware blocks
130
12.02 DIO2 CONF FW block: DIO2 (see above)
Selects whether DIO2 is used as a digital input, as a digital output or as a frequency input.
(0) Output DIO2 is used as a digital output.
(1) Input DIO2 is used as a digital input.
(2) Freq input DIO2 is used as a frequency input.
12.03 DIO3 CONF FW block: DIO3 (see above)
Selects whether DIO3 is used as a digital input, as a digital output or as a frequency output.
(0) Output DIO2 is used as a digital output.
(1) Input DIO2 is used as a digital input.
(2) Freq output DIO2 is used as a frequency output.
12.04 DIO1 OUT PTR FW block: DIO1 (see above)
Selects a drive signal to be connected to digital output DIO1 (when 12.01 DIO1 CONF is set to (0)
Output).
Bit pointer: Group, index and bit
12.05 DIO2 OUT PTR FW block: DIO2 (see above)
Selects a drive signal to be connected to digital output DIO2 (when 12.02 DIO2 CONF is set to (0)
Output).
Bit pointer: Group, index and bit
12.06 DIO3 OUT PTR FW block: DIO3 (see above)
Selects a drive signal to be connected to digital output DIO3 (when 12.03 DIO3 CONF is set to (0)
Output).
Bit pointer: Group, index and bit
12.07 DIO3 F OUT PTR FW block: DIO3 (see above)
Selects a drive signal to be connected to frequency output (when 12.03 DIO3 CONF is set to (2) Freq
output).
Value pointer: Group and index
12.08 DIO3 F MAX FW block: DIO3 (see above)
When 12.03 DIO3 CONF is set to (2) Freq output, defines the maximum DIO3 output frequency.
3…32768 Hz Maximum DIO3 output frequency.
12.09 DIO3 F MIN FW block: DIO3 (see above)
When 12.03 DIO3 CONF is set to (2) Freq output, defines the minimum DIO3 output frequency.
3…32768 Hz Minimum DIO3 output frequency.