Parameters and firmware blocks
131
12.10 DIO3 F MAX SCALE FW block: DIO3 (see above)
When 12.03 DIO3 CONF is set to (2) Freq output, defines the real value of the signal (selected by
parameter 12.07 DIO3 F OUT PTR) that corresponds to the maximum DIO3 frequency output value
(defined by parameter 12.08 DIO3 F MAX).
0…32768 Real signal value corresponding to maximum DIO3 output frequency.
12.11 DIO3 F MIN SCALE FW block: DIO3 (see above)
When 12.03 DIO3 CONF is set to (2) Freq output, defines the real value of the signal (selected by
parameter 12.07 DIO3 F OUT PTR) that corresponds to the minimum DIO3 frequency output value
(defined by parameter 12.09 DIO3 F MIN).
0…32768 Real signal value corresponding to minimum DIO3 output frequency.
Firmware block:
RO
(5)
Connects an actual signal to the relay
output. The block also shows the
relay output status.
Block outputs located in other
parameter groups
2.02 RO STATUS (page 94)
12.12 RO1 OUT PTR FW block: RO (see above)
Selects a drive signal to be connected to relay output RO1.
Bit pointer: Group, index and bit
Firmware block:
DI
(4)
Shows the status of the digital inputs.
Inverts the status of any DI if desired.
Block outputs located in other
parameter groups
2.01 DI STATUS (page 94)
f
DIO3
(Hz)
12.08
12.09
12.10 12.11
12.1012.11
12.08
12.09
Signal (real)
selected by
par. 12.07
f
DIO3
(Hz)
Signal (real)
selected by
par. 12.07
RO
17
TLF7 2 msec (2)
< 12.12 RO1 OUT PTR
[ BRAKE COMMAND.0 ]
(4 / 3.15.0)
2.02 RO STATUS
DI
16
TLF7 2 msec (1)
12.13 DI INVERT MASK
[ 0 0 0 00 0 ]
2.01 DI STATUS