Parameters and firmware blocks
142
16.11 USER IO SET LO FW block: None
Together with parameter 16.12 USER IO SET HI, selects the user parameter set when parameter
16.09 USER SET SEL is set to (10) IO mode. The status of the source defined by this parameter and
parameter 16.12 select the user parameter set as follows:
Bit pointer: Group, index and bit
16.12 USER IO SET HI FW block: None
See parameter 16.11 USER IO SET LO.
Bit pointer: Group, index and bit
16.13 TIME SOURCE PRIO FW block: None
Selects which real-time clock source is adopted by the drive as the master real-time clock. Some
selections specify multiple sources that are in order of priority.
(0) FB_D2D_MMI Fieldbus (highest priority); drive-to-drive link; man-machine interface
(control panel or PC).
(1) D2D_FB_MMI Drive-to-drive link (highest priority); fieldbus; man-machine interface
(control panel or PC).
(2) FB_D2D Fieldbus (highest priority); drive-to-drive link.
(3) D2D_FB Drive-to-drive link (highest priority); fieldbus.
(4) FB Only Fieldbus only.
(5) D2D Only Drive-to-drive link only.
(6) MMI_FB_D2D Man-machine interface (control panel or PC) (highest priority);
fieldbus; drive-to-drive link.
(7) MMI Only Man-machine interface (control panel or PC) only.
(8) Internal No external sources are used as master real-time clock.
16.20 DRIVE BOOT FW block: None
(0) No action Reboot not requested.
(1) Reboot drive Reboot the drive control unit.
Status of source
defined by par. 16.11
Status of source
defined by par. 16.12
User parameter set
selected
FALSE FALSE Set 1
TRUE FALSE Set 2
FALSE TRUE Set 3
TRUE TRUE Set 4