Fault tracing
326
0208 A2 INIT FAULT
(0x6100)
Application task creation fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0209 STACK ERROR
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0210 JMU MISSING
(0xFF61)
JMU Memory Unit is missing or
broken.
Check that the JMU is properly installed. If the
problem persists, replace the JMU.
0301 UFF FILE READ
(0x6300)
File read error
Note: This fault cannot be
reset.
Contact your local ABB representative.
0302 APPL DIR CREATION
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0303 FPGA CONFIG DIR
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0304 PU RATING ID
(0x5483)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0305 RATING DATABASE
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0306 LICENSING
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0307 DEFAULT FILE
(0x6100)
Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB representative.
0308 APPL FILE PAR CONF
(0x6300)
Corrupted application file
Note: This fault cannot be
reset.
Reload application.
If fault is still active, contact your local ABB
representative.
Code Fault
(fieldbus code)
Cause What to do