Fault tracing
327
0309 APPL LOADING
(0x6300)
Application file incompatible or
corrupted.
Note: This fault cannot be
reset.
Check the fault logger for a fault code
extension. See appropriate actions for each
extension below.
Fault code extension: 8 Template used in the application
incompatible with drive
firmware.
Change the template of the application in
DriveSPC.
Fault code extension: 10 Parameters defined in the
application conflict with existing
drive parameters.
Check the application for conflicting
parameters.
Fault code extension: 35 Application memory full. Reduce the application size and reload the
application.
Fault code extension: 38 Too many powerfail parameters Reduce the powerfail parameters from the
application.
Fault code extension: 39 Memory unit full Reduce the application size and reload the
application.
Fault code extension:
Other
Corrupted application file Reload application.
If fault is still active, contact your local ABB
representative.
0310 USERSET LOAD
(0xFF69)
Loading of user set is not
successfully completed
because:
- requested user set does not
exist
- user set is not compatible with
drive program
- drive has been switched off
during loading.
Reload.
0311 USERSET SAVE
(0xFF69)
User set is not saved because
of memory corruption.
Check the setting of parameter 95.01 CTRL
UNIT SUPPLY.
If the fault still occurs, contact your local ABB
representative.
0312 UFF OVERSIZE
(0x6300)
UFF file is too big. Contact your local ABB representative.
0313 UFF EOF
(0x6300)
UFF file structure failure Contact your local ABB representative.
0314 TECH LIB INTERFACE
(0x6100)
Incompatible firmware interface
Note: This fault cannot be
reset.
Contact your local ABB representative.
0315 RESTORE FILE
(0x630D)
Restoration of backed-up
parameters failed.
Contact your local ABB representative.
The fault is reset after a successful
restoration via the control panel or
DriveStudio.
Code Fault
(fieldbus code)
Cause What to do