Winder
3ADW000379R0501 DCS550 Manual e e
Winder commissioning
Commissioning hints
Follow the commissioning hints given by the online help using the question mark:
Following default settings should be kept:
WriteToSpdChain (61.02) = Auto
TensionOnCmd (61.07) = Auto
LineSpdNegLim (61.11) = Zero
LineSpdUnit (61.12) = %
AccFiltTime (62.18) = 100 ms
InerReleaseCmd (62.28) = Auto
TensSetCmd (63.04) = Auto
TensRampHoldCmd (63.09) = RelTensRamp
TensPulseCmd (63.13) = Auto
TTT Ref2In (63.19) = 6315 (tension reference)
FrictReleaseCmd (63.32) = Auto
To go back to normal speed control set WiProgCmd (66.01) = Stop, but keep the winder macro selected -
see WinderMacro (61.01) - this will keep the parameter settings.
Commissioning
1. Print out the winder overview diagram according to the chosen winder macro.
2. Specify the needed in- and outputs for the winder.
Example using serial communication:
Set CommandSel (10.01) = MainCtrlWord.
For additional winder commands use the auxiliary control bits of the MainCtrlWord (7.01), e.g.:
Rewind / Unwind command via bit 11, set WindUnwindCmd (61.04) = MCW B11.
Top / Bottom Command via bit 12, set TopBottomCmd (61.05) = MCW B12.
Winder on command via bit 13, set WinderOnCmd (61.06) = MCW B13.
Diameter set command via bit 14, set DiameterSetCmd (62.04) = MCW B14.
Write the line speed reference on SpeedRef (23.01) and set Ref1Sel (11.03) = SpeedRef2301.
Write the initial diameter on DiameterValue (62.03).
Write the tension reference e.g. on Data1 (19.01) and set TensRefIn (63.01) = 1901.
Example using serial local I/O:
Set CommandSel (10.01) = Local I/O.
For additional winder commands use digital inputs, e.g.:
DI1 for winder on command, set WinderOnCmd (61.06) = DI1.
DI2 for diameter set command, set DiameterSetCmd (62.04) = DI2.
DI3 for rewind / unwind command, set WindUnwindCmd (61.04) = DI3.
DI4 for Coast Stop, set Off2 (10.08) = DI4.
DI5 for E-stop, set E Stop (10.09) = DI5.
DI6 for reset, set Reset (10.03) = DI6
DI7 for On, set OnOff1 (10.15) = DI7.
DI8 for Run, set StartStop (10.16) = DI8.
AI1 for line speed reference, set Ref1Sel (11.03) = AI1.
AI2 for tension reference, set TensRefIn (63.01) = 516. see AI2 ValScaled (5.16).
AI3 for initial diameter use - see AI3 ValScaled (5.17) and DiameterValue (62.03) - AP block ParWrite: