171
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
0 actual motor speed is out of the zero speed limit
-------------------------------------------------
-----------------------------------------------------------------------------------------------------------------
EMFSpeed 1 M1SpeedFbSel (50.03) = EMF
0 no action
FaultOrAlarm 1 fault or alarm indication
0 no fault or alarm indication
DriveDirectionNeg 1 negative drive direction active - controlled by bit 8 of AuxCtrlWord2 (7.03)
0 positive drive direction active - controlled by bit 8 of AuxCtrlWord2 (7.03)
AutoReclosing 1 auto reclosing logic is active
0 no action
Int. Scaling: 1 == 1 Type: I Volatile: Y
8.03 LimWord (limit word, LW)
Limit word:
active limit
TorqMax (20.05) or TorqMaxAll (2.19)
TorqMin (20.06) or TorqMinAll (2.20)
TorqMaxSPC (20.07) or TorqMaxAll (2.19)
TorqMinSPC (20.08) or TorqMinAll (2.20)
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
IndepTorqMaxSPC (20.24)
IndepTorqMinSPC (20.25)
TorqMaxTref (20.09)
TorqMinTref (20.10)
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
M1SpeedMax (20.02)
M1SpeedMin (20.01)
M1CurLimBrdg1 (20.12)
M1CurLimBrdg2 (20.13)
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
-15 reserved
Int. Scaling: 1 == 1 Type: I Volatile: Y
8.05 DI StatWord (digital inputs status word, DISW)
Digital input word, shows the value of the digital inputs before inversion [DI1Invert (10.25), …, DI11Invert (10.35)]:
Name Comment / default setting
DI1 ConvFanAck (10.20), actual setting depends on macro
DI2 MotFanAck (10.06), actual setting depends on macro
DI3 MainContAck (10.21), actual setting depends on macro
DI4 Off2 (10.08), actual setting depends on macro
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
DI5 E Stop (10.09), actual setting depends on macro
DI6 Reset (10.03), actual setting depends on macro
DI7 OnOff (10.15), actual setting depends on macro
DI8 StartStop (10.16), actual setting depends on macro
----------------------------------------------------------------------------------------------------------------------------
--------------------------------------
DI9 DI1 of the extension IO defined by DIO ExtModule1 (98.03)
DI10 DI2 of the extension IO defined by DIO ExtModule1 (98.03)
DI11 DI3 of the extension IO defined by DIO ExtModule1 (98.03)
DI12 DI1 of the extension IO defined by DIO ExtModule2 (98.04). Only available for AP or overriding control.
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
DI13 DI2 of the extension IO defined by DIO ExtModule2 (98.04). Only available for AP or overriding control.
DI14 DI3 of the extension IO defined by DIO ExtModule2 (98.04). Only available for AP or overriding control.