Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
min.
max.
def.
unit
61.02 WriteToSpdChain (winder control, write to speed chain)
WriteToSpdChain (61.02)
controls the outputs of the winder blocks:
0 =
NotUsed constant 0; values of connected block outputs are not written to the speed control chain
1 =
Auto values of connected block outputs are written to the speed control chain, depending on
winder logic and winder macro, see WinderMacro (61.01), default
2 =
Release constant 1; values of connected block outputs are written to the speed control chain
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 2
4 =
DI1 1= written; 0 = not written
5 =
DI2 1= written; 0 = not written
6 =
DI3 1= written; 0 = not written
7 =
DI4 1= written; 0 = not written
8 =
DI5 1= written; 0 = not written
9 =
DI6 1= written; 0 = not written
10 =
DI7 1= written; 0 = not written
11 =
DI8 1= written; 0 = not written
12 =
DI9 1= written; 0 = not written; only available with digital extension board
13 =
DI10 1= written; 0 = not written; only available with digital extension board
14 =
DI11 1= written; 0 = not written; only available with digital extension board
15 =
MCW Bit11 1= written; 0 = not written; MainCtrlWord (7.01) bit 11
16 =
MCW Bit12 1= written; 0 = not written; MainCtrlWord (7.01) bit 12
17 =
MCW Bit13 1= written; 0 = not written; MainCtrlWord (7.01) bit 13
18 =
MCW Bit14 1= written; 0 = not written; MainCtrlWord (7.01) bit 14
19 =
MCW Bit15 1= written; 0 = not written; MainCtrlWord (7.01) bit 15
20 =
19.05Bit0 1= written; 0 = not written; Data5 (19.05) bit 0
21 =
19.05Bit1 1= written; 0 = not written; Data5 (19.05) bit 1
22 =
19.05Bit2 1= written; 0 = not written; Data5 (19.05) bit 2
23 =
19.05Bit3 1= written; 0 = not written; Data5 (19.05) bit 3
Note:
The connections itself are set by the selected winder macro and by the u
ser.
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
1905Bit3
Auto
-
61.03 Unused
61.04 WindUnwindCmd (winder control, rewind / unwind command)
Source for the rewind / unwind
command:
0 =
NotUsed no action
1 =
Winder constant 1; rewinder, default
2 =
Unwinder constant 0; unwinder
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 3
4 =
DI1 1= rewinder; 0 = unwinder
5
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
1905Bit3
Winder
-
rewind
unwind
rewind
unwind