236
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
61.05 TopBottomCmd (winder control, top / bottom command)
Source for the top (overwind) / bottom (underwind)
command:
NotUsed no action
Top constant 1; top (overwind) , default
Bottom constant 0; bottom (underwind)
WindCtrlWord according to WindCtrlWord (61.16) bit 4
DI1 1= Top (overwind); 0 = bottom (underwind)
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
61.06 WinderOnCmd (winder control, winder on command)
Source to release / block winder functions:
NotUsed constant 0; block winder functions
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
Release constant 1; release winder functions
WindCtrlWord according to WindCtrlWord (61.16) bit 5
DI1 1= release winder functions; 0 = block winder functions
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
61.07 TensionOnCmd (winder control, tension on command)
Source to release / block the independent speed controller torque limits
- IndepTorqMaxSPC (20.24) and -
- for tension control:
NotUsed constant 0; no tension control
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
Release constant 1; release tension control
WindCtrlWord according to WindCtrlWord (61.16) bit 8
DI1 1= release tension control; 0 = no tension control
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
top / overwind
bottom / underwind
top / overwind
bottom / underwind