246
Signal and parameter list
Signal / Parameter name
min.
max.
def.
unit
63.09 TensRampHoldCmd (tension reference, tension ramp hold command)
Source to hold / release the tension ramp:
0 =
RelTensRamp constant 0; release tension ramp, default
1 =
reserved
2 =
HoldTensRamp constant 1; hold tension ramp
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 11
4 =
DI1 1= hold tension ramp; 0 = release tension ramp
5
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
RelTensRamp
1905Bit3
RelTensRamp
-
63.10 Unused
63.11 TensPulseWidth (tension reference, tension pulse width)
Width of the tension pulse used to overcome the friction of the winder mechanics.
Int. Scaling: 1 == 1 ms Type: I Volatile: N
0
30000
0
ms
63.12 TensPulseLevel (tension reference, tension pulse level)
Level of the tension pulse used to overcome the friction of the winder mechanics in percent of maximum
tension.
Int. Scaling: 100 == 1 % Type: I Volatile: N
0
100
10
%
63.13 TensPulseCmd (tension reference, tension pulse command)
Source for command to release the tension pulse to overcome the friction of the winder mechanics:
0 =
NotUsed constant 0; no action
1 =
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
2 =
Release constant 1; release tension pulse once
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 12
4 =
DI1 1= release tension pulse; 0 = no action
5
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
1905Bit3
Auto
-
63.14 Unused
63.15 TensionRef (tension reference, output)
Output of the tension reference. Tension reference in percent of the maximum
tension.
Int. Scaling: 100 == 1 % Type: I Volatile: Y
-
-
-
%
63.16 - 63.17 Unused
Tension to torque:
For winders it is important that the tension fit to the web. With too low tension, the web does not wind correctly. With too
high tension, the web
might rip. This is the worst case, because the winder will accelerate, if there is no web break
monitoring.
The tension is a force measured in Newton [N]. When the tension is multiplied by the radius of the coil, the necessary
torque for the selected tension can be calculated. Most torque is needed with maximum diameter at lowest motor speed.
i
DF
T
*2
*
=
T [Nm] torque
F [N]
tension
D [m]
diameter
i
gear ratio (motor / load)
F
T
D
F
T
D

Table of Contents