EasyManua.ls Logo

ABB DCS550 - Page 249

ABB DCS550
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
249
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
min.
max.
def.
unit
63.32 FrictReleaseCmd (friction compensation, release command)
Source to
release / block the friction compensation:
0 =
NotUsed constant 0; block friction compensation
1 =
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
2 =
Release constant 1; release friction compensation
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 13
4 =
DI1 1= release friction compensation; 0 = block friction compensation
5
- 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
1905Bit3
Auto
-
63.33 Unused
63.34 FrictionComp (friction compensation, output)
Output of the friction compensation. Calculated friction compensation torque in percent of
MotNomTorque
(4.23)
.
Int. Scaling: 100 == 1 % Type: I Volatile: Y
-
-
-
%
Group 64: Write selection
Adder 1 provides two torque inputs. The sum of Add1 (64.06) can be written to other parameters by means of
Add1OutDest (64.01)
. Usually adder 1 is used to write on the torque limit of the speed controller.
Commissioning hint:
Add1Cmd (64.04) releases Add1 (64.06). The output is forced to zero if the switch is open.
64.01 Add1OutDest (adder 1, destination of output value)
Index pointer to the sink for adder 1 output value. The format is
-xxyy, with: - = negate output value, xx =
group and
yy = index.
As default, nothing is connected to the output
.
Int. Scaling: 1 == 1 Type: SI Volatile: N
-9999
9999
0
-
64.02 Add1In1 (adder 1, input 1)
Source (signal/parameter) for adder 1 input 1. The format is
-xxyy, with: - = negate output value, xx = group
and
yy = index.
Default setting of 6324 equals
TensToTorq (63.24).
Int. Scaling: 1 == 1 Type: SI Volatile: N
-9999
9999
6324
-
64.03 Add1In2 (adder 1, input 2)
Source (signal/parameter) for adder 1 input 2. The format is
-xxyy, with: - = negate output value, xx = group
and
yy = index.
As default, nothing is connected to the input
.
Int. Scaling: 1 == 1 Type: SI Volatile: N
-9999
9999
0
-
64.04 Add1ReleaseCmd (adder 1, release command)
Source to release / block adder 1:
0 =
NotUsed constant 0; block adder 1
1 =
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
2 =
Release constant 1; release adder 1
3 =
WindCtrlWord according to WindCtrlWord (61.16) bit 14
4 =
DI1 1= release adder 1; 0 = block adder 1
5
- 23 see WriteToSpdChain (61.02)
Note:
Blocking adder 1 forces its output to zero
- Add1 (64.06) = 0.
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
1905Bit3
Auto
-
64.05 Unused