250
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
64.06 Add1 (adder 1, output)
Output of adder 1 in percent of
MotNomTorque (4.23).
Int. Scaling: 100 == 1 % Type: I Volatile: Y
Adder 2 provides two torque inputs. The sum of Add2 (64.13) can be written to other parameters by means of
Add2OutDest (64.08)
. Usually adder 2 is used to write on the load compensation for inertia and friction compensation.
− Add2Cmd (64.11) releases Add2 (64.13). The output is forced to zero if the switch is open.
64.08 Add2OutDest (adder 2, destination of output value)
Index pointer to the sink for adder 2 output value. The format is
-xxyy, with: - = negate output value, xx =
yy = index.
nothing is connected to the output.
Int. Scaling: 1 == 1 Type: SI Volatile: N
64.09 Add2In1 (adder 2, input 1)
Source (signal/parameter) for adder 2 input 1. The format is
-xxyy, with: - = negate output value, xx = group
yy = index.
Default setting of 6230 equals
InertiaComp (62.30).
Int. Scaling: 1 == 1 Type: SI Volatile: N
64.10 Add2In2 (adder 2, input 2)
Source (signal/parameter) for adder 2 input 2. The format is
-xxyy, with: - = negate output value, xx = group
yy = index.
Default setting of 6334 equals
FrictionComp (63.34).
Int. Scaling: 1 == 1 Type: SI Volatile: N
64.11 Add2ReleaseCmd (adder 2, release command)
Source to
release / block adder2:
NotUsed constant 0; block adder 2
Auto depending on winder logic and winder macro, see WinderMacro (61.01), default
Release constant 1; release adder 2
WindCtrlWord according to WindCtrlWord (61.16) bit 15
DI1 1= release adder 2; 0 = block adder 2
- 23 see WriteToSpdChain (61.02)
Blocking adder 2 forces its output to zero
- Add2 (64.11) = 0.
Int. Scaling: 1 == 1 Type: C Volatile: N
64.13 Add2 (adder 2, output)
Output of adder 2 in percent of
MotNomTorque (4.23).
Int. Scaling: 100 == 1 % Type: I Volatile: Y