99.12 M1UsedFexType (used field exciter type)
Used field exciter type:
NotUsed no field exciter connected
OnBoard integrated 1-Q field exciter, default
If the fex type is changed, its new value is taken over after the next power
-up.
Int. Scaling: 1 == 1 Type: C Volatile: N
99.15 Pot1 (potentiometer 1)
Constant test reference 1 for the square wave generator.
The value is depending on the chosen destination of the square wave [e.g.
SqrWaveIndex (99.18) = 2301
SpeedScaleAct (2.29)]:
100 % voltage == 10,000
100 % current == 10,000
100 % torque == 10,000
100 % speed == SpeedScaleAct (2.29) == 20,000
Int. Scaling: 1 == 1 Type: SI Volatile: N
99.16 Pot2 (potentiometer 2)
Constant test reference 2 for the square wave generator.
The value is depending on the chosen destination of the square wave [e.g.
SqrWaveIndex (99.18) = 2301
SpeedScaleAct (2.29)]:
100 % voltage == 10,000
100 % current == 10,000
100 % torque == 10,000
100 % speed == SpeedScaleAct (2.29) == 20,000
Int. Scaling: 1 == 1 Type: SI Volatile: N
99.17 SqrWavePeriod (square wave period)
The time period for the square wave generator.
Int. Scaling: 100 == 1 s Type: I Volatile: N
99.18 SqrWaveIndex (square wave index)
Index pointer to the source
(signal/parameter) for the square wave generator. E.g. signal [e.g. 2301 equals
-up, SqrWaveIndex (99.18) is set back to 0 and thus disables the square wave generator.
Int. Scaling: 1 == 1 Type: I Volatile: Y
99.19 TestSignal (square wave signal form)
Signal forms for the square wave generator:
SquareWave a square wave is used, default
Triangle a triangle wave is used
SineWave a sine wave is used
Pot1 a constant value set with Pot1 (99.15) is used
Int. Scaling: 1 == 1 Type: C Volatile: Y