7: Operations, Administration & Maintenance
Duplicate event
A count of the OAMPDUs received that contain the Event Notification code. This counter is incremented on reception of a
valid frame, with:
DestinationField equal to the reserved multicast address for slow protocols.
LengthOrType field value equal to the reserved Type for slow protocols.
A slow protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Event Notification code.
The Sequence Number field is equal to the Sequence Number field of the last received Event Notification
OAMPDU.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Loopback control
A count of OAMPDUs received that contain the Loopback Control code. This counter is incremented on reception of a
valid frame, with:
DestinationField equal to the reserved multicast address for slow protocols.
LengthOrType field value equal to the reserved Type for slow protocols.
A slow protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Loopback Control code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Variable request
A count of OAMPDUs received that contain the Variable Request code. This counter is incremented on reception of a
valid frame, with:
DestinationField equal to the reserved multicast address for slow protocols.
LengthOrType field value equal to the reserved Type for slow protocols.
A slow protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Variable Request code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Variable response
A count of OAMPDUs received that contain the Variable Response code. This counter is incremented on reception of a
valid frame, with:
DestinationField equal to the reserved multicast address for slow protocols.
LengthOrType field value equal to the reserved Type for slow protocols.
A slow protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Variable Response code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).