7: Operations, Administration & Maintenance
Organization specific
A count of OAMPDUs received that contain the Organization Specific code. This counter is incremented on reception of a
valid frame, with:
DestinationField equal to the reserved multicast address for slow protocols.
LengthOrType field value equal to the reserved Type for slow protocols.
A slow protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Organization Specific code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Transmit
Unsupported codes
A count of OAMPDUs passed to the OAM subordinate sublayer for transmission that is not supported by the device. This
counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code for a
function that is not supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Information
A count of OAMPDUs passed to the OAM subordinate sublayer for transmission that contains the OAM Information code.
This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAMPDU
code indicating an Information OAMPDU.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Unique event
A count of OAMPDUs passed to the OAM subordinate sublayer for transmission that contains the Event Notification code.
This counter is incremented when a request service primitive is generated within the OAM sublayer.
A Slow_Protocols subtype value equal to the subtype reserved for OAM.
The OAMPDU code equals the Event Notification code.
The Sequence Number field is not equal to the Sequence Number field of the last transmitted Event Notification
OAMPDU.
Generalized nonresettable counter. This counter has a maximum increment rate of slow protocol frames (No more than
10 frames shall be transmitted in any one-second period).
Duplicate event
A count of OAMPDUs passed to the OAM subordinate sublayer for transmission that contains the Event Notification code.
This counter is incremented when a request service primitive is generated within the OAM sublayer.
The OAMPDU code equals the Event Notification code.
The Sequence Number field is equal to the Sequence Number field of the last transmitted Event Notification
OAMPDU.