9: Performance Assurance Agent
Continuity check threshold
Continuity check threshold. Number of consecutive sampling periods without receiving peer packets before declaring loss
of continuity.
One-way
Reference period
One-way reference period. This value needs to be at least 10 times the value of the sampling period.
Maximum delay
Maximum one-way average delay.
Delay threshold
Maximum one-way delay allowed in samples.
Average delay threshold
One-way average delay threshold.
Maximum delay variation
Maximum one-way delay variation allowed.
Delay variation threshold
One-way delay variation threshold in samples.
Average delay variation threshold
One-way average delay variation threshold.
NOTE: One-way delay measurements require time synchronization, via NTP, on units at each probe end.
Two-way
Reference period
Two-way reference period. This value needs to be at least 10 times the value of the sampling period.
Maximum delay
Maximum two-way average delay.
Delay threshold
Maximum two-way delay allowed in samples.
Average delay threshold
Two-way average delay threshold.