Preparing for Initial Use of Your New FieldFox 13
To conserve battery power:
Use Run/Hold to single-trigger a measurement when needed. Hold is shown on
the display.
Press System then Display then Brightness. Use the ▲|▼ arrows, the rotary
knob, or numeric keypad to adjust the brightness to dim the FieldFox display
as much as possible.
Briefly press the power button to switch to Stand By mode when the FieldFox
is not being used. Press again to restore power. All current settings are
preserved.
NOTE When powered by the battery only, the FieldFox can stay in Stand By mode for a
maximum of four hours and then it powers off automatically. When the relative
battery charge drops about 20%, the FieldFox will power off to preserve the
remaining charge.
To recharge a battery:
Use ONLY a FieldFox charger to recharge a battery.
The battery can be fully charged while in the FieldFox in about 4 hours with
the FieldFox either ON or OFF.
It can be fully charged externally using the external battery charger (Opt 872)
in about 4 hours.
When the battery is removed, the FieldFox can still be powered by the AC/DC
adapter.
FieldFox ON/OFF Settings
To turn power ON, briefly press the power button. The LED is green. Boot-up
takes about 1 minute.
To switch to Stand By mode (low battery drain), briefly press the power
button. The LED is orange and blinks. To turn power ON, briefly press the
power button. Power and settings are restored instantly. See the Note above
concerning Stand By mode.
To turn Power OFF (very low battery drain), press and hold the power button
until power is OFF - about 4 seconds. The LED is off.
Data and instrument state are NOT automatically saved when the FieldFox is
powered OFF. Learn how to save data and instrument state on page 151.
FieldFox High-Temperature Protection
The following features prevent degradation or damage in the event of high
internal temperatures in the FieldFox.
NOTE Do NOT store the FieldFox in the softcase while powered ON or in Stand By
mode.
How to monitor the internal FieldFox temperature:
Press System, then Service Diagnostics.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies FieldFox N9912A and is the answer not in the manual?

Agilent Technologies FieldFox N9912A Specifications

General IconGeneral
BrandAgilent Technologies
ModelFieldFox N9912A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals