Page #135 background image
Data Analysis Features 135
Data Analysis Features
The following features can be used after a measurement to analyze the results.
In this Chapter
All about Markers ................................................ 135
About Delta Markers .................................... 136
Marker Table .................................................. 138
Coupled Markers ........................................... 138
Marker Trace.................................................. 139
Marker Format .............................................. 139
Searching with Markers ............................... 140
What Is a ‘Peak’ ............................................. 143
Marker Functions .......................................... 144
SA Noise Marker ........................................... 144
SA Band Power Marker ............................... 145
SA Frequency Counter at Marker .............. 145
All about Limit Lines .......................................... 145
Relative Limit Lines ..................................... 146
Build From Trace .......................................... 147
Limit Options ................................................. 147
How to Save and Recall Limits ................... 148
All about Trace Math ........................................... 148
About Math Operations ................................ 149
All about Markers
Markers move along the X-axis range of the measurement trace to provide a
numerical readout of each measured data point. Markers also allow you to search
for specific Y-axis values.
A trace can contain up to six markers.
The marker readout on the FieldFox screen displays X and Y-axis information for
the current active marker ONLY.
A Marker Table can be displayed that allows you to simultaneously view X and Y-
axis information for all markers.
Markers can be used in CAT, SA, and NA Modes.
How to create Markers
Press Marker.
Then Markers 1...6 to select a marker to activate.
Then Normal to activate that marker. A marker is created on the trace in the
middle of the X-axis. That marker is now active.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies FieldFox N9912A and is the answer not in the manual?

Agilent Technologies FieldFox N9912A Specifications

General IconGeneral
BrandAgilent Technologies
ModelFieldFox N9912A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals