NTP 157 — Install an I-211M-H indoor ONT
NTP 157-4 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 157-1: I-211M-H indoor ONT
4 If desired, mount the OPSU remotely from the ONT (DLP 161).
5 Install the battery in the indoor ONT (DLP 162).
Retain the battery with the Velcro strap provided in the battery compartment.
6 Route the power, fiber optic, coaxial, POTS, and Ethernet cables (DLP 108).
7 Connect the Ethernet cable to an RJ-45 connector (DLP 101).
8 Connect the POTS cables to the IDC and RJ-11 connectors (DLP 123).
9 Connect the coaxial cable (DLP 116).
10 If used, configure the SLID (DLP 129).
11 Connect the fiber optic cable to an OptiTap connector (DLP 124). A fully cabled
I-211M-H indoor ONT is shown in Figure NTP 157-2.