1 —  ONT and MDU overview
1-22 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
If a currently provisioned SLID contains non-numeric digits, the ONT exits the SLID 
output mode. If a currently provisioned SLID contains only numeric digits, the value 
is displayed back to the installer using the POTS LED on the ONT. Each SLID 
number is determined by counting the number of times that the POTS LED on the 
ONT flashes as follows: 
• If the SLID is in decimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 second of green light followed by 1 
second of no light, repeated the number of times necessary to correspond to the 
number.
• For the number 0, the flash pattern is 0.5 second of green light followed by 1 second 
of no light repeated 10 times.
• There is a three second interval between digits.
• If the SLID is in hexadecimal format:
• For the numbers 1 to 9, the flash pattern is 0.5 second of green light followed by 0.5 
second of no light, repeated the number of times necessary to correspond to the 
number.
• For the number 0, the flash pattern is 0.5 second of green light followed by 0.5 
second of no light repeated 10 times.
• There is a three second interval between digits.
1.5 ONT management at a local site
ONT interfaces support the management of an ONT at a local site, and include:
• HTTP interface
• CLI interface
• HTTP interface for Package C ONTs
• CLI interface for Package C ONTs
• butt set
The HTTP and CLI interfaces provide access to utilities that allow a field technician 
to:
• retrieve product information about an ONT, such as vendor name, firmware, type 
of ONT, and serial number
• retrieve operational information about an ONT, to monitor events such as the 
operational states, uptime, receive signal strength indication (RSSI), status of 
LEDs, and ranging state of the ONT
• monitor a software download to an ONT
• reboot or reset an ONT to recover from connection, power, software download, 
and other failures
Note 1 — The SLID number displays more slowly in decimal format 
than in hexadecimal format.
Note 2 — The SLID number can be verified at any time by connecting 
a butt set to the first POTS port and dialing the “#” key.