NTP 160 — Install an I-211M-K or I-211M-L indoor ONT
NTP 160-8 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 160-5: Coiled cable routing (open view)
iii Cut the width of the cable off of the end of the grommet.
iv Reinstall the grommet into the slot over the cable.
v Coil the excess cable in a clockwise direction, allowing enough cable to
exit the lower right cable exit port; see Figure NTP 160-5.
vi Secure the fiber optic cable with the coil retention clamp; see
Figure NTP 160-5.
Coil retention clip
Cable feeds to ONT
(actual length varies, but a minimum of approximately 18 in.)
Buried cable
entry point
Grommet
Grommet
Aerial cable
entry point
(optional)
18812
Note — Observe the following:
• There must be adequate length for the fiber optic cable to curve
around and maintain minimum bend radius, enter into the ONT
enclosure and make the optical connection.
• There must be approximately 20 in. (50 cm) of cable exiting the FSST
at the right cable exit point.
• The FSST stores a maximum of 75 ft (22.86 m) of cable.