NTP 103 —  Install a B-0404G-B business ONT
NTP 103-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before installing the ONT. 
Procedure
Use this procedure to install a B-0404G-B business ONT. 
1 Prepare the cables at the site where the ONT will be installed (DLP 100). Also, 
locate the power source where the power converter will be installed.
2 Are any of the cables missing?
a If yes, go to step 3.
b If no, go to step 4.
3 Locate each missing cable and route them to the ONT as per local practices. 
Danger 1 —  Contact the local utility company before you connect the 
B-0404G-B Business ONT to the utilities.
Danger 2 —  Observe the local and national laws and regulations that 
may be applicable to this installation.
Warning 1 —  This equipment is ESD sensitive. Proper ESD protections 
should be used when connecting or removing the fiber optic cable to or 
from the ONT.
Warning 2 —  The intrabuilding port(s) of the equipment or 
subassembly is suitable for connection to intrabuilding or unexposed 
wiring or cabling only. The intrabuilding port(s) of the equipment or 
subassembly MUST NOT be metallically connected to interfaces that 
connect to the OSP or its wiring. These interfaces are designed for use 
as intrabuilding interfaces only (Type 2 or Type 4 ports as described in 
GR-1089-CORE, Issue 5) and require isolation from the exposed OSP 
cabling. The addition of Primary Protectors is not sufficient protection 
in order to connect these interfaces metallically to OSP wiring.
Caution —  Keep ONTs out of direct sunlight. Prolonged exposure to 
direct sunlight can damage the unit.
Note —  Observe the following:
• The ONT should be installed in accordance with the applicable 
requirements of the NEC or CEC. Local authorities and practices take 
precedent when there is conflict between the local standard and the 
NEC or CEC. 
• The ONT must be installed by qualified service personnel.
• See the “B-0404G-B unit data sheet” for the temperature ranges for 
ONTs.