14 — I-010G-A unit data sheet
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 14-7
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Table 14-9 I-010G-A indoor ONT environmental specifications
14.7 I-010G-A GEM ports and T-CONTs
Table 14-10 lists the maximum number of supported T-CONTs and GEM ports. Not
all ONTs will be supported in all of the releases indicated the table. See the
appropriate release Customer Release Notes for the most accurate list of supported
devices.
Table 14-10 I-010G-A indoor ONT capacity for GEM ports and T-CONTs per package and release
14.8 I-010G-A power support
The following power supply supports the I-010G-A indoor ONT. Click on the link
for more information.
• Leader Electronics 12W, 18W, and 24W ac/dc switching power supply unit data
sheet
14.9 I-010G-A functional blocks
Table 14-11 describes the supported interfaces for I-010G-A indoor ONTs.
Mounting method Temperature range and humidity Altitude
Desk or wall
mounted
Operating:
32°F to 104°F (0°C to 40°C) ambient
temperature
5% to 95% relative humidity, non-condensing
Maximum rate of temperature change is 32.9°F
(18.3°C) per hour
Maximum operating altitude is 10 000 ft (3048
m) above mean sea level
Storage:
-13°F to 133°F (-25°C to 55°C)
5% to 93% relative humidity, non-condensing
Maximum non-operating altitude is 40 000 ft
(12 192 m) above mean sea level
ONT or MDU Release Maximum Notes
Package A ONTs
GEM ports per indoor
or outdoor ONT
All 20 22 are present: 20 are available, 2
are reserved for OMCI and
debugging
T-CONTs per indoor or
outdoor ONT
All 21 22 are present: 21 are available, 1
is reserved for OMCI