NTP 121 —  Install an I-010G-B, I-020G-M, or I-040G-B indoor ONT
NTP 121-6 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
9 Connect the power cable with an 8-pin Molex connector to the ONT unit.
Figure NTP 121-4: Power connector pin configuration for I-010G-B, I-020G-M, and 
I-040G-B indoor ONTs
Figure NTP 121-5: Molex 8-pin connector
10 Power up the ONT unit by using the ON/OFF power switch.
Warning —  To avoid the possibility of damage to the pins on the power 
cable connector, carefully align the pins on the connector on the cable 
with the pin holes in the power connector on the ONT before making the 
connection. The pin hole configuration in the power connector on the 
ONT is shown in Figure NTP 121-4 while the pin arrangement on the 
Molex connector is shown in Figure NTP 121-5. 
Note —  When the I-040G-B ONT is used with the Delta DUPS-1215 4.5Ah 
UPS at ac line voltages above 200 V ac (either 50 or 60Hz), then the dc 
power cable must be equipped with an external clamp-on ferrite 
[Fair-Rite 0431167281 (1AB 09397 0026)]. The ferrite must be installed 
closer to the UPS than the ONT on the dc power cable. 
LAN 4 LAN 3 LAN 2 LAN 1
POWER ON/OFF
20533
POWER
Pin 2 Pin 8
Pin 1 Pin 3 Pin 7
20179