NTP 100 —  Install a B-0404-A
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 100-5
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Figure NTP 100-3: B-0404-A with wall mount bracket
6 Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
7 Connect up to four E1/T1 cables to the RJ-48C ports (DLP 104).
8 If used, configure the SLID (DLP 129).
9 Connect the fiber optic cable.
i Plug the OptiTap adaptor into the fiber optic port (DLP 124).
ii Plug the SC/APC adaptor into the fiber optic port (DLP 125).
10 If the B-0404-A is powered using:
a a power converter, go to step 11.
b a UPS, go to step 12.
11 Install the power converter. 
i Connect the ac power cable to the power converter (1AF 01226 AK), and plug 
the power converter into the electric outlet as shown in Figure NTP 100-4.
Warning —  Be careful to maintain a bend radius of no less than 1.5 
inches (3.8 cm) when connecting the fiber optic cable. Too small of a 
bend radius in the cable can result in damage to the optic fiber.
Note —  Observe the following:
• The power converter must be located within 5 ft (1.5 m) of the 
device.
• The power converter must be located within 6 ft (1.8 m) of an 
electrical outlet.
• Units must be powered by a Listed or CE approved and marked 
limited power source power supply with a minimum output rate of 
12 V dc, 2 A.
1 2 3 4
PON
1 2 3 4
20009
4
PON
3
2