NTP 107 — Replace a B-2404-P business ONT
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 107-3
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Figure NTP 107-1: B-2404-P business ONT connections
3 Replace the old unit with a new unit.
4 Connect up to two POTS cables to the RJ-11 ports (DLP 123).
5 Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
6 Connect up to four E1/T1 cables to the RJ-48C ports (DLP 104).
7 Connect the B-2404-P business ONT to a UPS.
i Install the UPS according to the manufacturer instruction. Be sure to read
and follow all safety, installation, maintenance, and service instructions.
ii Verify that the power cable terminates with an 8-pin connector as shown in
Figure NTP 107-2 and described in Table NTP 107-1.
Figure NTP 107-2: 8-pin connector