NTP 148 — Install an I-040G-R indoor ONT
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 148-3
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
4 Place the indoor ONT unit:
a On the flat surface, such as a desk, horizontally resting on its four feet as
shown in Figure NTP 148-1; go to step 5.
b On a wall (DLP 122).
5 Review the connection locations as shown in Figure NTP 148-1.
Figure NTP 148-1: I-040G-R indoor ONT connections
6 Connect the Ethernet cables to the RJ-45 ports (DLP 101).
7 Connect the SC/APC fiber optic cable (DLP 125).
8 Install the power supply according to manufacturer specifications.
9 Connect the power cable to the power connector.
10 If used, configure the SLID (DLP 6).
Note — The I-040G-R cannot be stacked with another ONT or with
other equipment. The ONT mounting requirements are:
allow a minimum 100 mm clearance above the top cover
allow a minimum 50 mm clearance from the side vents
do not place any heat source directly above the top cover or below
the bottom cover
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
23678
GE1
GE2
GE3
GE4
PWR
ON/OFF
RESET
PO
W
E
R
O
P
T
I
C
A
L
L
A
N
U
PD
AT
E
A
L
A
R
M
Ethernet
ports (RJ45)
Power
button
Reset
button
Power
connector
Fiber optic
connector

Table of Contents

Other manuals for Alcatel-Lucent 7330

Related product manuals