3 — ONT and MDU general and interface technical specifications
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 3-27
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
In the normal operating state, all the transmissions can be used for monitoring the
phase of the arriving transmission. Based on the monitoring transmission phase
information, the equalization delay can be updated.
3.14 ONT optical budget
This section provides the optical budget for all of the ONTs. Observe the safety
requirements with ONTs, which are Class 1 laser products. Figure 3-5 shows the
Class 1 laser product warning label attached to the ONT.
Figure 3-5 Class 1 laser product warning label
Table 3-16 lists ONT optical budget information.
Table 3-16 ONT optical budget
Warning — Operating equipment outside of its tested and
documented performance characteristics and causing an optical
overload may cause damage to equipment components, such as APD
receivers.
This can affect service delivery, and void any component or system
warranties.
CLASS 1 LASER PRODUCT
18256
Item Detail Minimum Typical Maximum
Operating temperature Ambient See the data sheets for each device
Transmitting budgets
Tx nominal bit rate — — 1244 Mb/s —
Tx/Rx line code Scrambled NRZ — — —
Tx central wavelength Operating
temperature
1290 nm — 1330 nm
Tx reflection of equipment At Tx wavelength — — –6 dB
Mask of Tx eye diagram G.984 burst mode — G.984 —
ORL of ODN at ONU Tx and Rx More than 32 dB — —
Tx mean launched optical power for
the ONT
At ONT optical
port
+0.5 dBm — +5.0 dBm
Tx launched optical power w/o input No input — Sensitivity –10
dB
—
Tx extinction ratio G.984 burst mode 10 dB — —
(1 of 2)