NTP 160 — Install an I-211M-K or I-211M-L indoor ONT
NTP 160-12 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 160-8: I-211M-L indoor ONT connections inside a Just Inside enclosure
7 Connect the ground wire (DLP 147). Optional, as required.
The ground is a range of 1/2 to 5/8 inch strip length with outer jacket aligned with
the outer surface of the enclosure.
8 Connect the Ethernet cable to the RJ-45 port (DLP 101).
9 Connect the POTS cables to the RJ-11 ports (DLP 123).
10 Connect the coaxial cable (DLP 116).
11 If used, configure the SLID (DLP 129).
12 Connect the SC/APC fiber optic cable (DLP 125).
13 Install the UPS according to manufacturer specifications (DLP 110).
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Silence
Alarm
System Status
Battery Power
Replace Battery
Auxillary Power
Battery
Emergency Use
22762
Power
cables
Fiber optic
cables
Ethernet
cable
POTS IDC
connector
Pots
cables
Ground
wire
Coaxial
cable
Locking
screw